Octoparms®腔静脉滤器预防肺栓塞安全性与有效性的多中心临床研究
作者:
通讯作者:
作者单位:

1.北京积水潭医院 血管外科, 北京 100035;2.南京医科大学附属南京医院(南京市第一医院) 介入科,江苏 南京 210006;3.徐州医科大学附属医院 介入放射科,江苏 徐州 221000;4.苏州大学附属第一医院 介入科,江苏 苏州 215006;5.郑州大学第一附属医院 腔内血管外科,河南 郑州 450052;6.福建医科大学附属协和医院 介入科,福建 福州 350001;7.湖南省人民医院 介入血管外科,湖南 长沙 410008;8.东南大学附属中大医院 介入与血管外科,江苏 南京 210000;9.河南省人民医院 血管外科,河南 郑州 450003;10.河北医科大学第三医院 血管外科,河北 石家庄 050051

作者简介:

田轩,北京积水潭医院副主任医师,主要从事急、慢性深静脉血栓的治疗、腔静脉滤器的应用、深静脉血栓后遗症、主髂、外周动脉疾病等方面的研究。

基金项目:

本刊编辑部全体人员,向长期以来关心、支持、订阅本刊的广大作者、读者致以诚挚的谢意!


A multicenter clinical trial of safety and effectiveness of Octoparms® vena cava filter in preventing pulmonary embolism
Author:
Affiliation:

1.Department of Vascular Surgery, Beijing Jishuitan Hospital, Beijing 100035, China;2.Department of Interventional Radiology, Nanjing Hospital (Nanjing First Hospital), Nanjing Medical University, Nanjing 210006, China;3.Department of Interventional Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu 221000, China;4.Department of Interventional Radiology, the First Affiliated Hospital of Soochow University, Suzhou, Jiangsu 215006, China;5.Department of Endovascular Surgery, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China;6.Department of Intervention, Union Hospital, Fujian Medical University, Fuzhou 350001,China;7.Department of Interventional Vascular Surgery, Hunan Provincial People's Hospital, Changsha 410008, China;8.Department of Interventional Radiology and Vascular Surgery, Affiliated Zhongda Hospital, School of Medicine, Southeast University, Nanjing 210000, China;9.Department of Vascular Surgery, Henan Provincial People's Hospital, Zhengzhou 450003, China;10.Department of Vascular Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang 050051, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 音频文件
  • |
  • 视频文件
    摘要:

    背景与目的 Octoparms?为首个国产伞状结构的可回收腔静脉滤器(VCF),为探讨该VCF预防肺栓塞(PE)的安全性和有效性,本研究采用多中心临床对照试验将其与进口VCF进行非劣效比较。方法 采用随机、多中心、阳性平行对照设计,将2017年9月—2019年3月全国10家中心符合入组标准的急性下肢深静脉血栓形成(DVT)患者,试验组与对照组按1∶1入组,对Octoparms?滤器与美国Celect滤器的安全性和有效性指标进行比较。结果 共188例患者纳入研究,试验组与对照组各94例。两组患者基线资料一致,滤器均顺利植入。试验组87例(92.6%)滤器成功取出,中位留置时间11(7~31)d,26例(27.6%)拦截血栓,对照组91例(96.8%)滤器成功取出,中位留置时间12(7~21)d,35例(37.2%)拦截血栓,滤器植入和取出过程两组均无PE症状发生,未见滤器严重移位、断裂,试验组滤器自居中效果优于对照组(P<0.05)。溶栓治疗104例(55.3%),2例(1.9%)滤器未取出,17例(16.3%)出血事件,未溶栓治疗84例(44.7%),8例(9.5%)滤器未取出,5例(5.9%)出血事件,溶栓与未溶栓患者间滤器取出率与出血事件发生率差异有统计学意义(χ2=3.928,P=0.048;χ2=4.858,P=0.028)。结论 用Octoparms?伞形VFC预防PE安全、有效,且整体效果与进口VCF一致。此外,溶栓治疗可有效减少深静脉血栓负荷,增加滤器取出率,但会增加患者出血风险。

    Abstract:

    Background and Aims Octoparms? is the first retrievable conical inferior vena cava filter (VCF) made in China. To investigate the safety and effectiveness of this VCF in prevention of pulmonary embolism (PE), this study was conducted for a non-inferiority comparison between this VCF and foreign imported VCF.Methods Using a randomized multicenter, positive parallel controlled design, the eligible patients with acute deep venous thrombosis (DVT) of lower extremities from 10 centers from September 2017 to March 2019 in China were enrolled and designated to study group and control group at a 1∶1 ratio. The variables concerning safety and effectiveness were compared between Octoparms? filter and USA Celect filter.Results A total of 188 patients were enrolled with 94 cases in each study group and control group. The baseline data of the two groups of patients were balanced, and all filters were successfully implanted. Filter was successfully retrieved in 87 cases (92.6%) in study group a the median retention time of 11 (7-31) d, and 26 cases (27.6%) thrombus interception. Filter was successfully retrieved in 91 cases (96.8%) in control group a the median retention time of 12 (7-21) d and 35 cases (37.2%) had thrombus interception. During the filter implantation and removal, no symptoms of PE occurred in both groups, and no severe filter shift or rupture was observed. The self-centering effect of filter in study group was better than that in control group (P<0.05). In the 104 cases (55.3%) undergoing thrombolytic therapy, the filter was not removed in 2 cases (1.9%) and the hemorrhage event occurred in 17 cases (16.3%); in the 84 cases (44.7%) who did not receive thrombolytic therapy, the filter was not removed in 8 cases (9.5%) and the hemorrhage event occurred 5 cases (5.9%). There were statistical differences in filter retrieval rate and incidence of hemorrhage event between patients with and without thrombolytic therapy (χ2=3.928, P=0.048; χ2=4.858, P=0.028).Conclusion Using Octoparms? conical VCF for prevention of PE is safe and effective, and the overall efficacy is similar with that of foreign imported VCF. In addition, thrombolytic therapy can effectively reduce the load of DVT and increase the filter removal rate, but it will increase the risk of hemorrhage in patients.

    表 3 滤器置入前、取出前和取出后6个月DVT和PE情况[n(%)]Table 3 The DVT and PE status before filter implantation, before filter removal and 6 months after filter removal [n(%)]
    图1 Octoparms®VCF的临床应用相关图片 A:滤器同轴释放(OTW同轴释放);B:右侧股静脉入路滤器释放后造影;C:左侧股静脉入路滤器释放后造影;D:滤器内血栓形成Fig.1 Pictures of the clinical application of Octoparms®VCF A: Filter insertion using coaxial sheath system (OTW balloon dilatation catheter); B: Angiography after filter placement in the right femoral vein; C: Angiography after filter placement in the left femoral vein; D: Thrombosis in the filter
    表 4 DVT治疗方法和并发症情况[n(%)]Table 4 The relationship between DVT treatment methods and complications [n(%)]
    参考文献
    相似文献
    引证文献
引用本文

田轩,刘建龙,顾建平,徐浩,倪才方,李震,杨维竹,向华,滕皋军,翟水亭,张彦荣,李金勇. Octoparms®腔静脉滤器预防肺栓塞安全性与有效性的多中心临床研究[J].中国普通外科杂志,2021,30(12):1395-1402.
DOI:10.7659/j. issn.1005-6947.2021.12.002

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
历史
  • 收稿日期:2021-09-18
  • 最后修改日期:2021-12-14
  • 录用日期:
  • 在线发布日期: 2022-01-07